Jiangbian Power江变电力Menu

Oil-immersed and cast resin transformers up to 35 kV

Made in Xuzhou, Jiangsu. Up to 31 500 kVA, at 50 or 60 Hz. From 630 to 2 500 kVA at 10 kV, the S22-M and SCB18 are energy-efficiency Grade 1, and a 2 000 kVA unit of each passed type tests to IEC 60076 in May 2026.

Grid voltages we build for

  • 6 kV
  • 10 kV
  • 11 kV
  • 13.2 kV
  • 13.8 kV
  • 15 kV
  • 20 kV
  • 22 kV
  • 33 kV
  • 34.5 kV
  • 35 kV

What we build

Oil-immersed and cast resin dry-type transformers from 6 to 35 kV and up to 31 500 kVA. Listed by model series.

[TBC: kVA range and voltage classes per series]

Oil-immersed transformer with radiator banks, a conservator and an on-load tap-changer compartment, in the factory hall

Oil-immersed transformers

Oil-immersed transformer with radiators and a conservator, in the factory hall.

  • S22-M

    Energy-efficiency Grade 1 (NX1) under GB 20052-2024 across the filed range, 630 to 2 500 kVA at 10 kV. Fully sealed tank.

    Type-tested May 2026 to IEC 60076 and GB standards, 2 000 kVA unit

    See S22-M

  • SZ20

    On-load tap-changer, 35 kV class.

    Type-tested 2025 to GB standards, 8 000 kVA, 35/10.5 kV

    See SZ20

Ask about these series

We also build compact substations, and special and non-standard transformers to your specification.

See the full range

Built for your grid

Pick your country to see the grid voltages and frequency we build for, and which channel reaches us first.

Another country

Grid we build for

Your grid

Grid voltages
6 to 35 kV
Frequency
50 or 60 Hz
Low-voltage side
0.4, 0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Russia

Grid voltages
6, 10 or 35 kV
Frequency
50 Hz
Low-voltage side
0.4 kV

Talk to us first on

Email1667005235@qq.com

then Phone: +86 159 0520 4400

If a messenger doesn't work where you are, use email or the quote form.

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Kazakhstan

Grid voltages
6, 10 or 35 kV
Frequency
50 Hz
Low-voltage side
0.4, 0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Kyrgyzstan

Grid voltages
10 or 35 kV
Frequency
50 Hz
Low-voltage side
0.4, 0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Uzbekistan

Grid voltages
6, 10 or 35 kV
Frequency
50 Hz
Low-voltage side
0.4, 0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Iraq

Grid voltages
11 or 33 kV
Frequency
50 Hz
Low-voltage side
0.4, 0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Nigeria

Grid voltages
11 or 33 kV
Frequency
50 Hz
Low-voltage side
0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Kenya

Grid voltages
11 or 33 kV
Frequency
50 Hz
Low-voltage side
0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Ghana

Grid voltages
11 or 33 kV
Frequency
50 Hz
Low-voltage side
0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Egypt

Grid voltages
11 or 22 kV
Frequency
50 Hz
Low-voltage side
0.4, 0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Indonesia

Grid voltages
20 kV
Frequency
50 Hz
Low-voltage side
0.4, 0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Grid we build for

Philippines

Grid voltages
13.2, 13.8 or 34.5 kV
Frequency
60 Hz
Low-voltage side
0.4, 0.415 or 0.433 kV

Talk to us first on

WhatsApp+86 159 0520 4400

then Email: 1667005235@qq.com

Quote for this grid

These are the voltages we build for. The Grade 1 and IEC 60076 records are for 10 kV units. [TBC: kVA range and voltage classes per series]

Tested, not claimed

Third-party labs type-tested these units. Select a line to find it on the certificate.

S22-M, 2 000 kVA

S22-M-2000/10-NX1, oil-immersed power transformer, 2 000 kVA, 10 kV. Tested 18 to 22 May 2026; report issued 24 May 2026.

Lab
China National Center for Quality Inspection and Test of Electrical Apparatus Products. CMA 230008349829, CNAS L1020, ILAC-MRA
Standards
With 10 Chinese GB and JB/T standards, including GB 20052-2024
Result
Energy-efficiency Grade 1 under GB 20052-2024

Measured losses

Each bar shows the measured loss against the Grade 1 limit in GB 20052-2024 (the line).

  • No-load loss

    Measured 989.0 W. The Grade 1 limit is 1 085 W. 8.8 % below. Rated 1 080 W.

  • Load loss

    Measured 12 659.0 W. The Grade 1 limit is 13 180 W. 4.0 % below. Rated 13 175 W.

Documents

Type-test certificate 20260592 for S22-M-2000/10-NX1, issued by the China National Center for Quality Inspection and Test of Electrical Apparatus Products. Issue date and signature blurred.
Show the whole page
  • Type-test certificate 20260592
  • Report 26M1152-S
  • Energy-efficiency report CEL-A-20260523-951581

A type-test certificate applies to the sample tested in its report.

Ask for the full report

All tests, standards and filing for S22-M
Unit
Tests
Standards
Filing
DQJC-2026-10438: S22-M, 630 to 2 500 kVA, 10 kV, issued 5 June 2026

SCB18, 2 000 kVA

SCB18-2000/10-NX1, dry-type cast resin transformer, 2 000 kVA, 10 kV. Tested 19 to 22 May 2026.

Lab
China National Center for Quality Inspection and Test of Electrical Apparatus Products. CMA 230008349829, CNAS L1020, ILAC-MRA
Standards
With 9 Chinese GB and JB/T standards, including GB 20052-2024
Result
Energy-efficiency Grade 1 under GB 20052-2024

Measured losses

Each bar shows the measured loss against the Grade 1 limit in GB 20052-2024 (the line).

  • No-load loss

    Measured 1 428.0 W. The Grade 1 limit is 1 760 W. 18.9 % below. Rated 1 755 W.

  • Load loss at 145 °C

    Measured [TBC: value only partly legible on our copy of the report]. The Grade 1 limit is 14 005 W. Rated 14 000 W.

Documents

Type-test certificate 20260564 for SCB18-2000/10-NX1, issued by the China National Center for Quality Inspection and Test of Electrical Apparatus Products. Issue date and signature blurred.
Show the whole page
  • Type-test certificate 20260564
  • Report 26N0992-S
  • Energy-efficiency report CEL-A-20260524-227886 (lab no. 26N0993-S)

A type-test certificate applies to the sample tested in its report.

Ask for the full report

All tests, standards and filing for SCB18
Unit
Tests
Standards
Filing
DQJC-2026-10457: SCB18, 630 to 2 500 kVA, 10 kV, issued 9 June 2026

SZ20, 8 000 kVA

SZ20-8000/35, oil-immersed power transformer with on-load tap-changer, 8 000 kVA, 35/10.5 kV. Tested 13 July to 12 August 2025; issued 12 August 2025.

Lab
Anhui Product Quality Supervision & Inspection Research Institute
Standards
GB/T 1094.1, .2, .3, .5 and .10With GB/T 6451-2023, GB/T 7595-2017 and JB/T 501-2021
Result
PassedType test, including measurements before and after the short-circuit withstand test

[TBC: measured losses for the SZ20]

Documents

  • Report (2025) 皖检JZ字第0594号

Ask for the full report

All tests, standards and filing for SZ20
Unit
SZ20-8000/35, oil-immersed power transformer with on-load tap-changer, 8 000 kVA, 35/10.5 kV
Tests
Type test, including measurements before and after the short-circuit withstand test
Standards
GB/T 1094.1, GB/T 1094.2, GB/T 1094.3, GB/T 1094.5, GB/T 1094.10, GB/T 6451-2023, GB/T 7595-2017, JB/T 501-2021

The factory in Xuzhou

No. 300 Xuhai Road, Xuzhuang Town, Xuzhou Economic and Technological Development Zone, Xuzhou, Jiangsu, China

Quality management certified to ISO 9001:2015 by ZQHX Certification Center, valid until 1 April 2027.

Visit the factory, or inspect by live video.

SGS or BV welcome for third‑party inspection.

[TBC: factory area, staff and annual output]

About the factory

Watch the factory film (36 s)

  1. Blue slitting line cutting a coil of steel, with cut sheets stacked on a pallet beside it

    Cutting coil steel on the slitting line.

  2. A coil wrapped in insulation paper turning on a winding machine

    Winding a coil.

  3. Three wound coils assembled on a transformer core, with insulated leads

    A core and coil assembly.

  4. Finished oil-immersed transformers with corrugated tanks, some with conservators, standing in the factory hall

    Finished oil-immersed transformers in the hall.

  5. A cast resin transformer with red coils in front of the transformer test station in the factory hall

    Cast resin transformers in the factory hall.

  6. Plywood crates standing on the factory floor

    Plywood crates on the factory floor.

Tell us what you need

The fields follow a transformer spec sheet. Fill in what you know and leave the rest blank.

We reply in English within 8 hours, 08:00 to 20:00 China time (UTC+8), every day.

This form isn't connected to an inbox yet, so requests sent here are not delivered. Use email or a messenger listed on this page.

How we reply

Give at least one: email or phone.

With country code, for example +7 or +234.

Ratings (optional)Rated power, voltages, frequency and quantity

Per unit. Leave blank if not fixed yet.

Number of units.

For example 10, 11, 33 or 35.

For example 0.4 or 0.415.

Frequency

Vector group, cooling, tap-changer, standards, destination port, delivery date.

We use these details only to answer your request. Read the privacy notice.